Urinary symptoms and cystometry findings in patients with multiple system atrophy: A tertiary care experience
Gourav Sannyasi1, Anupam Gupta2
, Hafis Rahman3, Navin B Prakash2, Vikram Holla4
1Department of Physical Medicine & Rehabilitation, Manipal Hospital, Kolkata, India
2Department of Neurological Rehabilitation, National Institute of Mental Health and Neurosciences (NIMHANS), Bangalore India
3Department of Physical Medicine & Rehabilitation, Rehabilitation Centre, Areekode, India
4Department of Neurology, National Institute of Mental Health & Neuro Sciences, Bengaluru, India
Keywords: Filling and voiding cystometry, multiple system atrophy, urinary symptoms.
Abstract
Objectives: This study aims to characterize urinary symptoms and evaluate urodynamic findings using filling and voiding cystometry in participants with multiple system atrophy (MSA), and to guide the management of bladder dysfunction based on cystometric findings through pharmacological, behavioral, and supportive interventions.
Patients and methods: Between November 2022 and June 2023, a total of 27 patients who were diagnosed with MSA and experienced urinary symptoms were screened. Among them, those who were referred to our neurorehabilitation unit for rehabilitation consultation and bladder management were included. Sociodemographic data of the patients, illness duration, type and duration of urinary complaints such as voiding difficulty, nocturia, and urinary urge incontinence were documented. All medical comorbidities and medications, including those prescribed for MSA, were also noted. All patients underwent urodynamic evaluation, including filling and voiding cystometry.
Results: Of a total of 27 patients, 23 were male and four were female with a mean age of 57.6 ± 7 (range, 48 to 77) years. The mean duration of illness was 29.7 ± 20 (range, 4 to 84) months, while the mean duration of urinary symptoms was 19 ± 16 (range, 3 to 66) months. The most common urinary symptoms were urgency and increased frequency (n = 18, 66.7%), feeling of incomplete evacuation and urge urinary incontinence (n = 16, 59.3%), nocturia (n = 13, 48%), retention of urine (n = 10, 37%), straining to void (n = 8, 29.6%), stress incontinence (n = 3, 11.1%), and incontinence without awareness (n = 2, 7.4%). According to cystometry, 77.8% participants had neurogenic detrusor overactivity (n = 21), with more than half had associated detrusor sphincter dyssynergia (n = 15, 55.6%). Six participants had acontractile/hypocontractile detrusor. The bladder management was based on cystometry findings and consisted of pharmacotherapy, behavioral, and supportive therapy.
Conclusion: Urinary symptoms are common and diverse in patients with MSA. Early cystometric evaluation and appropriate management guided by the findings may help reduce disease-related morbidity and improve quality of life.
Citation: Sannyasi G, Gupta A, Rahman H, Prakash NB, Holla V. Urinary symptoms and cystometry findings in patients with multiple system atrophy: A tertiary care experience. Arch ISPRM 2026;1(4):318-325. https://doi.org/10.5606/archisprm.2026.113
G.S.: Literature review, data collection & processing, writing article; A.G.: Idea/supervision, design, method, data analysis, manuscript editing , critical review; H.R.: Data collection & processing, literature review; N.B.P.: Supervision, design, critical review, idea; V.H.: Idea, resource person, design, materials.
The authors declare that there are no conflicts of interest with respect to the research, authorship, and/or publication of this article.
This research received no specific grant from any funding agency in the public, commercial, or not‑for‑profit sectors.
Data Availability
The datasets generated and/or analyzed during the current study are available from the corresponding author on reasonable request.
AI Disclosure
The authors declare that artificial intelligence (AI) tools were not used, or were used solely for language editing, and had no role in data analysis, interpretation, or the formulation of conclusions. All scientific content, data interpretation, and conclusions are the sole responsibility of the authors. The authors further confirm that AI tools were not used to generate, fabricate, or ‘hallucinate’ references, and that all references have been carefully verified for accuracy.